The best Guide to Quality Control of Fiber Optic Cable in Underground Electrical Energy Transmission Line Project
Type sample and routine tests shall be undertaken on non metallic
underground fiber optic cable, all fittings & accessories and the
optical fibers in a accordance with the requirements of this specification,
CCITT G652, IEC 793 and IEC 794 as appropriate.
Contract drawings previously submitted to the Engineer shall be available at the time of testing.
Contract drawings previously submitted to the Engineer shall be available at the time of testing.
The contractor / supplier shall give the Engineer the requisite
period of notice prior to undertaking the tests and shall submit to the
Engineer a test program and procedures for approval.
What should be the Optical Fibers?
Optical fibres shall be tested in accordance with the requirements
of CCITT |G652 and IEC 793 as appropriate.
How Would be the Optical Joint Boxes to joint the Fiber Cable?
Optical joint boxes shall be visually inspected to ensure they
meet the specified requirement.
If the external housing or its door show any signs of distortion than the box shall be rejected.
Details of the inspection shall be recorded and shall be made available to the Engineer upon request.
If the external housing or its door show any signs of distortion than the box shall be rejected.
Details of the inspection shall be recorded and shall be made available to the Engineer upon request.
Why Need Non-metallic Underground Fibre Optic Cable?
Non-metallic underground fibre optic cable and the optical shall
be tested in accordance with the requirements of CCIT G652, IFC 793 and IFC 794
as appropriate.
How Test Fibre Optic Cables?
All fibre optic cables shall be tested prior to dispatch using an
OTDR on each fibre.
Test Certificates of Fiber Optic Cables
Test records covering Type and Sample tests shall be made
available to the Engineer.
Certificates of Conformity
When requested copies of the following certificates / records
shall also be forwarded:
· Optical joint boxes visual inspection records.
· Routine test records
· The records of the OTDR test results.
How Ensure Factory Acceptance Teats for Fiber Optic Cable?
In case the FOC’s and fittings are a significant portion of the
Contract the Employer reserves the right to attend Routine tests at works of
the supplier.
The Bidder shall include in its bid, all costs (airfares accommodation etc.) associated with two members of the Employer’s staff ant the Employer’s Representative, if applicable attending and witnessing the above factory acceptance tests.
The Bidder shall include in its bid, all costs (airfares accommodation etc.) associated with two members of the Employer’s staff ant the Employer’s Representative, if applicable attending and witnessing the above factory acceptance tests.
TESTING AN COMMISSIONING OF OPTICAL CABLES
The contractor shall provide details of all proposed type,
routine, sample, pre-commissioning and commissioning tests to be carried out
each FOC cable type, for each drum of cable delivered and each FOC link
installed as appropriate.
Routine Test of Materials for Fiber Optic CAble
The Contractor shall provide test certificates for routine tests
which are performed to ensure basic materials meet the requirements of the FOC
Types.
What Sample Test of Fiber Optic Cable to Carry Out?
Contractors shall provide test certificates of sample tests which
are performed on each drum of cable manufactured. Such certificates shall
include as a minimum:
· Mode diameter on each fibre
· Cut-off wave length on each fibre
· Optical Domain Reflectometer (OTDR) scan results for each fibre
at the system wave length.
Sponsored:Routine Test of Fiber Optic Cable
Contractors shall provide test certificates of routine tests which
are performed on each cable Batch manufactured. The routine test shall include
as a minimum:
· Water immersion / penetration tests for all FOC type.
· Cable tensile strength tests for all FOC type.
· Repeat bending performance test for all FOC type.
· Fibre strain test for all FOC type.
· Cladding diameter measurement for all fibres on all FOC type.
· Mode field concentricity error measurement on all fibre on all FOC
type.
SINGLE MODE OPTICAL FIBRE CABLE REQUIREMENTS
Particulars
|
Requirements
|
|||
Coating
diameter
|
μm
|
245 + 10
|
||
Cladding
diameter
|
μm
|
125 + 1
|
||
Cladding
non-circularity
|
%
|
< 1
|
||
Mode
field diameter
|
μm
|
9 + 0.5
|
||
Mode
field concentricity error
|
μm
|
< 1
|
||
Cut
off wave length
|
nm
|
< 1270
|
||
Attenuation
at
(maximum
average)
|
1285
nm
|
1330
|
dB/km
|
< 0.4
|
Attenuation
at
(maximum
average)
|
1550
nm
|
dB/km
|
< 0.25
|
|
Zero
dispersion wave length
|
nm
|
< 1310
|
||
Chromatic
dispersion at
|
1285
nm
|
1330
|
dB/(km-nm)
|
< 3.5
|
Chromatic
dispersion at
|
1550
nm
|
dB/(km-nm)
|
< 20
|
|
Individual
splice loss
|
dB
|
<
0.15
|
||
Mean
splice loss
|
dB
|
<
0.1
|
What References Standards Should be followed to Construct Fiber Optic Cable?
The reference standards and other documents referred to in this Section of the Specification are listed below:
IEC 529: Classification of decrees of protection provided by enclosures
IEC 793- 1: Optical Fibres Part 1: Generic Specification
IEC 793-2: Optical Fibres Part 2: Product Specification
IEC 794-1: Optical Fibre Cable Part 1: Generic Specification
IEC 794-2: Optical Fibre Cable Part 2: Product Specification
BS 729: Specification for hot dip galvanised coatings on iron and steel articles
BS 1490: Specification for Aluminium and aluminium alloy ingots and castings for general engineering purposes
BS 3100: Specification for steel castings for general engineering purposes
BS 3643: Ingot zinc
BS 4190: Specification for ISO Metric hexagon bolts, screws and nuts
BS EN 1676: Aluminium and aluminium alloys - Alloyed ingots forremelting
BS EN10025: Specification for hot rolled products of non-alloying structural steels and their technical delivery requirements.
CCITT G652: Characteristics of single mode optical fibre cable.
IEC 529: Classification of decrees of protection provided by enclosures
IEC 793- 1: Optical Fibres Part 1: Generic Specification
IEC 793-2: Optical Fibres Part 2: Product Specification
IEC 794-1: Optical Fibre Cable Part 1: Generic Specification
IEC 794-2: Optical Fibre Cable Part 2: Product Specification
BS 729: Specification for hot dip galvanised coatings on iron and steel articles
BS 1490: Specification for Aluminium and aluminium alloy ingots and castings for general engineering purposes
BS 3100: Specification for steel castings for general engineering purposes
BS 3643: Ingot zinc
BS 4190: Specification for ISO Metric hexagon bolts, screws and nuts
BS EN 1676: Aluminium and aluminium alloys - Alloyed ingots forremelting
BS EN10025: Specification for hot rolled products of non-alloying structural steels and their technical delivery requirements.
CCITT G652: Characteristics of single mode optical fibre cable.
I am completely satisfied with the techniques you have written over here on the optical cable. The effort you made in this article is truly nice. If anybody is seeking for Cable Certifier, then precisionfiberproductsis good choice.