CONTENTS
1. GENERAL.......................................................................................................................3
1.1
Scope..............................................................................................................................3
2. INTRODUCTION OF OTB.........................................................................................3
3. OTB
REQUIREMENTS..............................................................................................3
3.1
Description...................................................................................................................3
3.2
Drawings......................................................................................................................4
3.3 Dimension and Material
Specifications......................................................................5
4. Environmental PERFORMANCE……………………...................................................6
4.1 Vibration Test..............................................................................................................6
4.2 Thermal Cycling
Test..................................................................................................6
4.3 Axial Pull-out
Test......................................................................................................7
4.4 Water protection test (IP55) for Outdoor
Type.........................................................7
5.
PACKING &
MARKING...................................................................................8
5.1
Packing........................................................................................................................8
5.2
Marking.......................................................................................................................8
1. GENERAL
1.1 Scope
This internal
specification includes the structure, characteristics and packing/marking
information of FOTB-I/O-DC SERIES. The FOTB-I/O-DC SERIES is designed to provide
many important functions in the FTTx Network such as the optical signal
distribution, cable storage and fiber termination/splicing. The FOTB-I/O-DC
SERIES shall be produced by the ISO-9001 certified production facilities. And
all processes from product design to packaging were controlled by the
Quality-Control System.
Model
|
Description
|
FOTB-I/O-DC SERIES
|
FOTB: Optical Termination
Box
|
I/: Indoor/Outdoor
installation
| |
DC: Dual Compartment
|
2. INTRODUCTION of
OTB
LS Optical Termination Box is designed to terminate,
splice and interconnect fiber optic cables in an outdoor environment. This box
accommodates FTTH applications by mounting to the exterior surface of a
dwelling and connecting between the distribution cable and drops routed to
individual living units.
3. OTB
REQUIREMENTS
3.1 Description
The box is divided into two sections with distribution
cable routed into one section and drop cable routed into the other section. The
cables meet at a splicing field that includes termination for the distribution
cable and parking for the drop cables or the splice field that can be
configured with splice trays for splicing the cable. The box may be
pre-terminated on the distribution side with an outside plant cable stub so
that the unit is quickly connected to the plant. It may be pre-wired with
pigtails on the drop side so that individual drops routed into the unit can be
spliced to the connectorized pigtails.
<Fig. 1. Photo of FOTB-DC
Series>
3.2 Drawings
<Fig. 2. Ref. Drawings of FOTB-I/O-DC
SERIES>
3.3 Dimension and Material
Specifications
- Indoor
Parameter
|
12FO
|
24FO
|
36FO
|
48FO
| |
General
|
Dimension
(LXWxH)(mm)
|
350x320x80
|
350x320x80
|
350x320x125
|
350x320x150
|
Color
|
Ivory /
Beige / Black
| ||||
Material
|
SPCC
| ||||
Cable
Entry
|
No. of Entry
(In/Out)
|
2 /
2
| |||
Dia. of
Inlet (mm)
|
Max.
25
| ||||
Dia. of
Outlet (mm)
|
Max.
25
| ||||
Adaptor*)
|
Type
|
SC(Default)
/ LC / FC
| |||
No. of
Adaptor
|
Max.
12
|
Max.
24
|
Max.
36
|
Max
48
| |
Connection
|
Splice
Method
|
Fusion /
Adaptor
| |||
No. of
splice tray
|
1
|
2
|
3
|
4
| |
Capacity per
tray
|
Max.
12
| ||||
Total
Capacity
|
Max.
12
|
Max.
24
|
Max.
36
|
Max.
48
| |
Application
|
Installation
Environment
|
Indoor
| |||
Installation
type
|
STD: Wall
mount(Option for Pole mount)
| ||||
Locking
Method
|
Key
Lock
|
* Adaptor panel type can be substituted other type
which can accommodate Simplex LC, Duplex LC, Duplex SC adaptor and other
types.
- Outdoor
Parameter
|
12FO
|
24FO
|
36FO
|
48FO
| |
General
|
Dimension
(LXWxH)(mm)
|
350x320x100
|
350x320x100
|
350x320x150
|
350x320x170
|
Color
|
Ivory /
Beige / Black
| ||||
Material
|
Aluminum (or
Stainless Steel)
| ||||
Cable
Entry
|
No. of Entry
(In/Out)
|
2 /
2
(or In case
of drop entries: 12 / 24 / 36 / 48)
| |||
Dia. of
Inlet (mm)
|
13 ~
18
| ||||
Dia. of
Outlet (mm)
|
13 ~ 18(or
In case of drop entries: 3 ~ 6)
| ||||
Adaptor*)
|
Type
|
SC(Default)
/ LC / FC
| |||
No. of
Adaptor
|
Max.
12
|
Max.
24
|
Max.
36
|
Max
48
| |
Connection
|
Splice
Method
|
Fusion /
Adaptor
| |||
No. of
splice tray
|
1
|
2
|
3
|
4
| |
Capacity per
tray
|
Max.
12
| ||||
Total
Capacity
|
Max.
12
|
Max.
24
|
Max.
36
|
Max.
48
| |
Application
|
Installation
Environment
|
Indoor
| |||
Installation
type
|
STD: Wall
mount(Option for Pole mount)
| ||||
Grounding
|
Available
| ||||
Locking
Method
|
Key
Lock
|
* Adaptor panel type can be substituted other type
which can accommodate Simplex LC, Duplex LC, Duplex SC adaptor and other
types.
4. ENVIRONMENTAL
PERFORMANCE
4.1 Vibration test
Test Procedure |
1. Fix the fiber distribution panel on the vibration
tester
2. Vibrate for 1hours with amplitude 1mm, frequency
10-55-10Hz in 10minutes
3. Check the mechanical
damage
| |||||
Requirements
|
There should be no cracks, fractures and
disconnection.
| |||||
Test
Assembly
|
[Test
Equipment]
| |||||
Test
Result
|
1.
Cracks/fracture/disconnection
|
None
| ||||
2. Mechanical damage
|
None
| |||||
Judgment
|
Complied
|
4.2 Thermal cycling
test
Test
Procedure
|
1. Put fiber distribution panel in the
tester.
2. Thermal cycle: 20 → 2
→
50(relative humidity 80%) →
20℃
(Maintaining 2hr at each
Temp.)
3. Temp. rising/falling: 1 ℃/min
4. 2 cycling test(17hr
12min)
5. Check corrosion and mechanical
damage.
| |
Requirements
|
1. There should be no
corrosion
2. There should be no mechanical
damage.
| |
Test
Assembly
|
| |
Test
Result
|
1.Crossion
|
None
|
2. Mechanical damage
|
None
| |
Judgment
|
Complied
|
4.3 Axial Pull-out
Test
4.4 Water protection test (IP55) for Outdoor
Type
Test Procedures
|
The board is tested by means of a spray head or a
flushing pipe which is aimed at it from all sides according to the standardized
testing time / volume flow.
| |||||
Requirements.
|
Water Penetration
| |||||
Test Assemble
|
| |||||
Test Result
|
Water Penetration
|
None
| ||||
Judgment
|
Pass
| |||||
Remark
|
|
5. PACKING AND
MARKING
5.1 Packing
5.1.1 The LS FOTB-I/O-DC SERIES shall be well packed in
individual box.
5.1.2 The LS FOTB-I/O-DC SERIES shall have necessary
accessory for installation, I.e. user manual
etc.
5.1.3 Each LS FOTB-I/O-DC SERIES is to be packed with a
protective material.
5.2 Marking
Details given below shall be distinctly marked with a
weather proof material on the both outer sides of the shipping carton. Other
shipping mark is also available if requested by
customer.
- Product
item
- Country of
origin
- Manufacturer’s
name and/or trademark
- Gross
weight
- Caution mark,
I.e. maximum stacking height
<The end of
specification>
Hi, really appreciate you for this awesome article you have covered all the pin points of the topic in this article keep up the good work. Cheers! Fibre Optic Distribution Box
ReplyDeleteYellowstonesjacket is worldwide online store where we offer best & high quality leather jacket including cosplay, jacket made with real leather material. Yellowstones jackets are one of the best brands. We also have a huge collection of Halloween Costumes and jackets offering you in very reasonable price with worldwide free shipping delivery on your door steps!Beth Dutton Blue Coat